    Brand Name : CONSNANT
    Model Number : CNH110
    Certification : CE, ISO9001, ISO14001
    Price : Negotiable
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 50000 pieces per year
    Delivery Time : 5-7 days for sample order, 7-15 days for mass production
    • Product Details
    • Company Profile

    Online 70HZ High Frequency UPS System Zero Transfer Double Conversion PFC

    CNH110 HIGH FREQUENCY ONLINE UPS

    Key Feature:

    Zero Transfer time
    True Double Conversion Online UPS, Provide most comprehensive protect mission critical equipment from wide range power quality issues

    DSP Digital Control Based
    Advance DSP base digital control bring high performance of high input Power factor, low distortion , supply the load with perfect sine wave AC power supply

    Ultra Wide Input Mains range
    Strong compatible with ultra with electric environment, stay well with ultra wide range mains of 90V~300V, 40~70Hz ,dramatically reduce battery discharge , prolong battery life

    Best Loading Capability
    Up to 0.9 Output Power Factor, 50/60 Hz Automatically adapting, selectable voltage , perfectly match all kind of application

    Genset Compatible
    Capable of work with wide range of Genset, isolate fluctuation and noise from Genset , provide stable and clean power supply to the user equipment.

    High Input power factor
    Thanks to digital controlled PFC Technology, >0.99 input power factor, effectively avoid power pollution , save energy expense for customer

    Reliable design
    Made with strong Glass fiber base (FR4) double side PCB, company with large span component, greatly improve reliability in harsh environment, Well designed ventilation and conformal coating , avoid dust accumulation ,improve resistant to corrosion

    Open to customization
    Based on powerful controller and open architecture, the product is able to be customized to match need of integration of automatic system or intelligent supervisory system

    Specification Refer:


    ModelC1KC1KSC2KC2KSC3KC3KS
    CapacityVA/W1KVA/800W2KVA/1.6KW3KVA/2.4KW
    TopologyDouble Conversion Online UPS
    PhaseSingle Phase Input Single Phase Output
    Mains InputWiringL/N+PE
    Rated Voltage208/220/230/240VAC
    Voltage Range90~300VAC
    Frequency Range40Hz-70Hz
    Input Power Factor≥0.99
    AC OutputWiringL/N+PE
    Output Voltage208/220/230/240VAC
    Voltage Regulation±1%
    Output Frequency50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)
    WaveformPure Sine Wave
    Distortion(THDV%)<2%(Linear Load)
    <7%(None-Linear Load)
    Over load capacity1Min@105%~125%Rated Load
    30Sec.@125%~150%Razoad
    EfficiencyAC/AC Mode88%89%90%
    DC/AC Mode86%87%88%
    Battery
    &
    Charge
    Rated Battery Voltage ①24VDC
    Internal
    36VDC
    External
    48VDC
    Internal
    72VDC
    External
    72VDC
    Internal
    96VDC
    External
    Battery Capacity12V/7AHExternal Battery Depends12V/7AHExternal Battery Depends12V/7AHExternal Battery Depends
    Backup Time>6mins @ Half Load>6mins @ Half Load>6mins @ Half Load
    Charging CurrentStandard Model with Internal Battery:1A
    Long Backup Time Model :4A
    PhysicalChassis StyleRACK / Tower (separated)
    Tower Dimension
    1KS: 145(W)X220(H)x250(D)mm
    1K, 2KS: 145(W)X220(H)x318(D)mm
    2K:145(W)X220(H)x390(D)mm
    3K/3KS: 190(W) x 318(H) x 368(D)mm
    Rack Dimension3KR: 438mm(W) x 88mm(2U)(H) x 500mm(D) Include Internal Battery
    1KR/1KSR/2KR/2KSR/3KSR: 438mm(W) x 88mm(2U)(H) x 360mm(D)
    Weight (kg)8.94.2145.921.68.3
    HMILCD DISPLAYInput Mains Voltage, Frequency, Load level, Operation Mode, Health Status
    Standards Communication1. RS232 PORT
    2. NMC Card: Support remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown
    Optional Extension CardCMC MODBUS Card, USB Card, Relay Card
    (Needs assembly according to order request before shipping)
    Operating Environment
    Endurance
    Temperature range-10~50oC
    Relative Humidity0-98%(Non-condensing)
    Acoustics Noise<55dB @ 1 meters

    ModelC1K-LVC1KS-LVC2K-LVC2KS-LVC3K-LVC3KS-LVC5K-LVC5KS-LV
    CapacityVA/W1KVA/800W2KVA/1.6KW3KVA/2.4KW5KVA/5.4KW
    TopologyDouble Conversion Online UPS
    PhaseSingle Phase Input Single Phase Output
    Mains InputWiring1 phase 3 wires (L/N+PE)
    Rated Voltage110/115/120/127VAC
    Voltage RangeLine-Neutral: 90~300VAC
    Frequency Range40Hz-70Hz
    Input Power Factor≥0.99
    AC OutputWiring1 phase L/N+PE
    Output Voltage110/115/120/127VAC
    Voltage Regulation±2%
    Output Frequency50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)
    WaveformPure Sine Wave
    Distortion(THDV%)<2%(Linear Load)
    <7%(None-Linear Load)
    Over load capacity1Min@105%~125%Rated Load
    30Sec.@125%~150%Razoad
    10min@105%~125%
    60s@125%~150%
    0.5S@>150%
    EfficiencyAC/AC Mode88%89%90%92%
    DC/AC Mode86%87%88%90%
    Battery
    &
    Charge
    Rated Battery Voltage ①24VDC
    Internal
    36VDC
    External
    48VDC
    Internal
    72VDC
    External
    72VDC
    Internal
    96VDC
    External
    144VDC
    Internal
    192VDC
    External
    Battery Capacity12V/7AHExternal Battery Depends12V/7AHExternal Battery Depends12V/7AHExternal Battery Depends12V/7AHExternal Battery Depends
    Backup Time>6mins @ Half Load>6mins @ Half Load>6mins @ Half Load>6mins @ Half Load
    Charging CurrentStandard Model with Internal Battery:1A
    Long Backup Time Model :4A
    PhysicalChassis StyleRACK / Tower (separated)
    Tower Dimension
    1KS: 145(W)X220(H)x250(D)mm
    1K, 2KS: 145(W)X220(H)x318(D)mm
    2K:145(W)X220(H)x390(D)mm
    3K/3KS: 190(W) x 318(H) x 368(D)mm
    C5KS-LV
    190 x 360x 528
    Rack Dimension3KR: 438mm(W) x 88mm(2U)(H) x 500mm(D) Include Internal Battery
    1KR/1KSR/2KR/2KSR/3KSR: 438mm(W) x 88mm(2U)(H) x 360mm(D)
    Weight (kg)8.94.2145.921.68.33716
    HMILCD DISPLAYInput Mains Voltage, Frequency, Load level, Operation Mode, Health Status
    Standards Communication1. RS232 PORT
    2. NMC Card: Support remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown
    Optional Extension CardCMC MODBUS Card, USB Card, Relay Card
    (Needs assembly according to order request before shipping)
    Operating Environment
    Endurance
    Temperature range-10~50oC
    Relative Humidity0-98%(Non-condensing)
    Acoustics Noise<55dB @ 1 meters

    ModelC6KC6KSC8KC8KSC10KC10KS
    CapacityVA/W6KVA/5.4KW8KVA/7.2KW10KVA/9KW
    TopologyDouble Conversion Online UPS
    PhaseSingle Phase Input Single Phase Output
    Mains InputWiringL/N+PE
    Rated Voltage208/220/230/240VAC
    Voltage Range90~300VAC
    Frequency Range40Hz-70Hz
    Input Power Factor≥0.99
    AC OutputWiringL/N+PE
    Output Voltage208/220/230/240VAC
    Voltage Regulation±1%
    Output Frequency50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)
    WaveformPure Sine Wave
    Distortion(THDV%)<2%(Linear Load)
    <7%(None-Linear Load)
    Over load capacity10Min@105%~125%Rated Load
    60Sec.@125%~150%Rated Load
    0.5Sec.@>150%Rated Load
    EfficiencyAC/AC Mode>93%
    DC/AC Mode>91%
    Battery
    &
    Charge
    Rated Battery Voltage ①144VDC
    Internal
    192/240VDC
    External
    192VDC
    Internal
    192/240VDC
    External
    192VDC
    Internal
    192/240VDC
    External
    Battery Capacity12V/7AHExternal Battery Depends12V/7AHExternal Battery Depends12V/7AHExternal Battery Depends
    Backup Time>6mins @ Half Load>6mins @ Half Load>6mins @ Half Load
    Charging CurrentStandard Model with Internal Battery:1A
    Long Backup Time Model :4A
    PhysicalChassis StyleRACK / Tower (separated)
    Tower Dimension
    C6KS, C8KS, C10kS: 190(W)X340(H)x534(D)mm
    C6K:190(W)X360(H)x534(D)mm
    C8K, C10K: 190(W)X456(H)x534(D)
    Rack DimensionUPS: 438mm(W) x 88mm(2U)(H) x 500mm(D) without Internal Battery
    Battery Pack: 438mm(W) x 88mm(2U)(H) x500mm(D)
    Weight (kg)8.94.2145.921.68.3
    HMILCD DISPLAYInput Mains Voltage, Frequency, Load level, Operation Mode, Health Status
    Standards Communication1. RS232 PORT
    2. NMC Card: Support remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown
    Optional Extension CardCMC MODBUS Card, USB Card, Relay Card
    (Needs assembly according to order request before shipping)
    Operating Environment
    Endurance
    Temperature range-10~50oC
    Relative Humidity0-98%(Non-condensing)
    Acoustics Noise<55dB @ 1 meters

    Model3C10K3C10KS3C15K3C15KS3C20K3C20KS
    CapacityVA/W10KVA/9KW15KVA/13.5KW20KVA/18KW
    TopologyDouble Conversion Online UPS
    PhaseSingle Phase Input Single Phase Output OR
    3 Phases Input Single Phase Output
    Mains InputWiringSingle Phase L/N+PE OR
    3 Phases (L1,L2,L3,N)/N+PE
    Rated Voltage208/220/230/240VAC
    Voltage RangeLine-Neutral 90~300VAC
    Line-Line 150~500VAC
    Frequency Range40Hz-70Hz
    Input Power Factor≥0.99
    AC OutputWiringL/N+PE
    Output Voltage208/220/230/240VAC
    Voltage Regulation±1%
    Output Frequency50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)
    WaveformPure Sine Wave
    Distortion(THDV%)<2%(Linear Load)
    <7%(None-Linear Load)
    Over load capacity10Min@105%~125%Rated Load
    60Sec.@125%~150%Rated Load
    0.5Sec.@>150%Rated Load
    EfficiencyAC/AC Mode>94%
    DC/AC Mode>92%
    Battery
    &
    Charge
    Rated Battery Voltage ①192VDC
    Internal
    192/240VDC
    External
    192VDC
    Internal
    192/240VDC
    External
    192VDC
    Internal
    192/240VDC
    External
    Battery Capacity12V/7AH x 16pcsExternal Battery Depends12V/7AH x 32pcsExternal Battery Depends12V/7AH x 32pcsExternal Battery Depends
    Backup Time>6mins @ Half Load>6mins @ Half Load>6mins @ Half Load
    Charging CurrentStandard Model with Internal Battery:1A
    Long Backup Time Model :4A
    PhysicalChassis StyleRACK / Tower (separated)
    Tower Dimension
    3C10kS: 190(W)X340(H)x535(D)mm
    3C15/20kS: 238(W)X528(H)x540(D)mm
    Rack Dimension3C10kSR: 438mm(W) x 132mm(3U)(H) x 500mm(D)
    3C15kSR/3C20kSR:4U 438(W)x176(H)x530(D)MM
    Weight (kg)8.94.2145.921.68.3
    HMILCD DISPLAYInput Mains Voltage, Frequency, Load level, Operation Mode, Health Status
    Standards Communication1. RS232 PORT
    2. NMC Card: Support remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown
    Optional Extension CardCMC MODBUS Card, USB Card, Relay Card
    (Needs assembly according to order request before shipping)
    Operating Environment
    Endurance
    Temperature range-10~50oC
    Relative Humidity0-98%(Non-condensing)
    Acoustics Noise<60dB @ 1 meters


    Remark:
    ① Battery Capacity and voltage is open to customization
    ② Dimension might vary for different bezel
    ③ The socket and terminal configuration on the rear panel may be different for countries or regions according to order
    ④ More parameter customization,please contact sales representative


    Certification

    Quality Online 70HZ High Frequency UPS System Zero Transfer Double Conversion PFC for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Consnant Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)