Sign In | Join Free | My himfr.com
Home > Hybrid Solar Inverter >

Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage

    Buy cheap Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage from wholesalers
     
    Buy cheap Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage from wholesalers
    • Buy cheap Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage from wholesalers

    Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage

    Ask Lasest Price
    Brand Name : CONSNANT
    Model Number : HT4830S80-145 | HT4840S80-145 | HT4850S80-145 | HT4825U80-145 | HT4830U80-145 | HT4835U80-145
    Certification : CE(EN62109); EN61000; C2
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 1000 pieces per month
    Delivery Time : 5-8 days for sample order, 15-21 days for large quantity
    • Product Details
    • Company Profile

    Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage

    Mutiple Mode Hybrid PV Energy Storage Grid Solar Inverter


    Product Instruction:


    HT series is a new hybrid PV energy storage inverter controller integrating PV energy storage,mains charging

    and storage and AC sine wave output. Using DSP control through advanced control algorithms, it comes with high

    response speed, high reliability, high industrialization standard and other characteristics.

    Four charging modes are available: only PV, mains priority, PV priority, and hybrid charging by mains & PV;

    two output modes: inverter and mains are available to meet different application needs.


    Key Feature:

    1. Full digital voltage; current double closed loop control, combined with advanced SPWM technology to output

    pure sine wave.
    2. Two output modes and 4 charging modes are available for choice.
    3. AdvancedMPPT technology with efficiency up to 99.9%.
    4. LCD screen design, with 3 LED indicators, for dynamic display of system data and run status; ON/OFF rocker

    switch controls AC output.
    5. Power saving mode reduces no-load loss.
    6. Intelligent variable speed fan ensures efficient heat dissipation, and thereby extends system life.
    7. Double lithium battery activation modes: mains and PV, and supports lead-acid battery and lithium battery

    access.
    8. Multiple protections provide 360 ° all-round protection for the system. Complete protections include multi-electrical

    appliance air switch short circuit protection, overvoltage and undervoltage protection, overload protection, back-flow

    protection, etc.
    9. Horizontal installation facilitates cabinet combination installation.
    10. Lithium battery can be activated by both mains and PV panel.


    Specification Reference:

    ModelHT4830S80-145HT4840S80-145HT4850S80-145HT4825U80-145HT4830U80-145HT4835U80-145
    Mains mode
    Rated input voltage220/230Vac110/120Vac
    Input voltage range(170Vac~280Vac) ±2%
    (90Vac-280Vac)±2%
    (90Vac~140Vac) ±2%
    Frequency range47±0.3Hz ~ 55±0.3Hz (50Hz);
    57±0.3Hz ~ 65±0.3Hz (60Hz);
    Conversion time10ms (typical)
    (bypass and inverter)
    Maximum bypass overload current40A
    Inverter mode
    Output voltage waveformPure sine wave
    Rated output power (VA)3000(2600/2700
    /3000)
    4000(3480/360
    3800/4000)
    5000(4350/4500
    /4800/5000)
    2500(2000/2180
    /2290)
    3000(2500/2600
    /2750)
    3500(2900/3000
    /3200)
    Rated output power (W)3000(2600/2700
    /3000)
    4000(3480/360
    3800/4000)
    5000(4350/4500
    /4800/5000)
    2500(2000/2180
    /2290)
    3000(2500/2600
    /2750)
    3500(2900/3000
    /3200)
    Rated output voltage (Vac)230Vac(200/208/220/240Vac Settable)120Vac(100/105/110Vac Settable)
    Output voltage error±5%
    Output frequency range (Hz)50Hz ± 0.3Hz
    60Hz ± 0.3Hz
    Efficiency>92%>91%
    Overload protection(102%<load<125%) ±10%: Report error and turn off output after 5 minutes;
    (125%<load<150%) ±10%: Report error and turn off output after 10 seconds;
    Load>150% ±10%: Report error and turn off output after 5 seconds;
    (102%<load<110%) ±10%: Report error and turn off output after 5 minutes;
    (110%<load<125%) ±10%: Report error and turn off output after 10 seconds;
    Load>125% ±10%: Report error and turn off output after 5 seconds;
    Peak power6000VA8000VA10000VA4000VA4500VA5000VA
    Loaded motor capacity2HP3HP4HP1HP2HP2HP
    Bypass circuit breaker specification63A
    Rated battery input voltage48V (minimum starting voltage 44V)
    Battery voltage range40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery...LCD screen can be set)
    Eco modeLoad ””≤ 50W
    AC charging
    Maximum charge current0-60A0-40A
    Charge
    current error
    ± 5Adc
    Charge voltage range40 - 58Vdc40 - 60Vdc
    Circuit breaker specification(AC IN) 63A/(BAT) 125A
    PC charge
    Maximum PV open circuit voltage145Vdc
    PV operating voltage range60-145Vdc
    MPPT voltage range60-115Vdc
    Battery voltage range40-60Vdc
    Maximum output power4200W
    PV charge current range (settable)0-80A
    Charge short circuit protectionBAT circuit breaker and fuse
    Wiring protectionReverse polarity protection
    Hybrid charging Max charger current specifications (AC charger+PV charger)
    Max charger current(can be set)0-140A0-120A
    Certified specification
    Specification certificationCE(EN62109)
    EMC certification levelEN61000, C2
    Operating temperature range-15°C to 55°C
    Storage temperature range-25°C ~ 60°C
    RH range5% to 95% (conformal coating protection)
    Noise≤”60dB
    Heat dissipationForced air cooling, adjustable air speed

    Product Maintenance and Fault Handling:

    No.ProtectionsRemarks
    1PV current/power limiting protectionWhen charging current or power of the PV array configured exceeds the PV rated, it will charge at the rated.
    2PV night reverse-current protectionAt night, the battery is prevented from discharging through the PV module because the battery voltage is greater than the voltage of PV module.
    3Mains input over voltage protectionWhen the mains voltage exceeds 280V (230V model) or 140V (120V model), the mains charging will be stopped and switched to the inverter mode.
    4Mains input under
    voltage protection
    When the mains voltage is lower than 170V (230V model /UPS mode) or 90V (120V model or APL mode), the mains charging will be stopped and switched to the inverter mode.
    5Battery over voltage protectionWhen the battery voltage reaches the overvoltage disconnection point, the PV and the mains will be automatically stopped to charge the battery to prevent the battery from being overcharged and damaged.

    FaultsHandling measures
    No display on the screenCheck if the battery air switch or the PV air switch has been closed;
    if the switch is in the "ON" state; press any button on the screen to exit the screen sleep mode.
    Battery overvoltage protectionMeasure if the battery voltage exceeds rated, and turn off the PV array air switch and Mains air switch.
    Battery undervoltage protectionCharge the battery until it returns to the low voltage disconnection recovery voltage.
    Fan failureCheck if the fan is not turning or blocked by foreign object.
    Heat sink over temperature protectionWhen the temperature of the device is cooled below the recovery temperature, normal charge and discharge control is resumed.
    Bypass overload protection, inverter overload protection① Reduce the use of power equipment;
    ② Restart the unit to resume load output.
    Inverter short circuit protection① Check the load connection carefully and clear the short-circuit fault points;
    ② Re-power up to resume load output.
    Quality Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage for sale